Coated XPS boards with heating-pipe grooves
This grooved tile backer board combines an XPS foam core with a mortar coating described as approximately 1 mm on either side. The published range lists 20–50 mm overall thickness and 1200 × 600 mm panels, with customized dimensions and groove patterns available for discussion.
Groove options are listed for 16 mm or 20 mm pipe. Confirm the selected diameter and layout, together with the layers and floor finish above the panel, before ordering.
Published specifications
| PROPERTIES | SPECIFICATIONS |
|---|---|
| Thickness of Mortar Layer | About 1mm |
| Total Thickness of Products | 20mm-50mm |
| Panel Size | Length: 1200mm Width: 600mm or Customized |
| Size of Grooves | Apply to φ16mm / φ20mm pipe or Customized |
| Groove Pattern | Could be customized |
| Density of XPS Foam Board | 30-45kg/m3 |
| Thermal Conductivity at 10℃ | 0.030-0.036w/m.k |
| Compressive Strength (10% Deflection) | 300KPa++ |
| Tensile adhesive strength | 0.5MPa++ |
| Water Absorption (2-days immersion) | 0.2% by volume |
| Water Vapour Permeability,ng(m.s.Pa) | 1.50% |
| Flammability of XPS Foam Board | B2 Grade |
Request the current configuration-specific datasheet and test methods. The water-vapour permeability entry has inconsistent units in the published table and must be confirmed before use in calculations. Confirm the applicable standard and report for the stated fire classification.
Specify the heating-floor construction
- Pipe diameter, spacing, groove pattern and turning details.
- Panel thickness, dimensions and fixing or bonding method.
- Substrate condition and any required covering or load-distribution layers.
- Compatible floor finish, adhesive and installation sequence.
- Wet-area joints, penetrations and waterproofing connections where applicable.
Do not assume that tile, wood, laminate or carpet can be applied directly to every configuration. Confirm the complete system instructions and required performance documentation. Heating response and temperature distribution depend on the full design, not the board alone.
Order Grooved Panels from an Approved Layout
Separate each pipe diameter, panel thickness and groove pattern in the order schedule. Provide the straight runs, returns and connection details on the floor drawing, and confirm the number of each panel pattern after the layout is reviewed. A sample board and pipe-fit check should identify the agreed configuration before a repeat order.
Request a grooved backer-board quotation with board counts, drawing revision and delivery destination. Add your pack-label and handling requirements using the backer-board sample and packing checklist, or browse the tile backer board range for other surface and layout requirements.
Request project supply
Send the floor plan, pipe specification, intended finish, board thickness, quantities and delivery destination. Include any packaging or project approval requirements.
For a different facing construction, compare the aluminum-faced XPS radiant panel. For non-grooved tiled assemblies, review the XPS core tile backer board for wet areas.